°í°´¼¾ÅÍ

Á¦Ç°Ä«Å×°í¸®

¿Â¶óÀι®ÀÇ ±â¼úÀÚ·á½Ç ¿À½Ã´Â±æ
  > Àü±âÀüÀÚ°èÃø±â > ¹èÀü¹Ý½ÃÇè¿ë > --->µðÁöÅиÖƼ¹ÌÅÍ

--->µðÁöÅиÖƼ¹ÌÅÍ

À̹ÌÁö detail
Digital Multimeter(FLUKE/110 Serise), 0.7%
  • Á¦Á¶»çFLUKE
  • ¸ðµ¨¸í110 Serise
  • ÁÖ¿ä±â´É AC/DC, Àü¾Ð, Àü·ù, ÀúÇ× ÃøÁ¤±â´É

»óÇ°»ó¼¼Á¤º¸





•True RMS measurements
•Three year warranty
•6000 count resolution
•Digital display with analog bargraph
•AC/DC current measurements (111, 112)
•Backlight display (112)
•Manual and automatic ranging
•Display Hold
•Frequency and capacitance measurements
•Resistance, continuity and diode measurements
•Min-max-average recording
•Easy battery exchange without opening the case
•Closed case calibration through front panel
•Compact case with separate holster
•EN61010-1 CAT III 600V
•Three year warranty ​

 

Specifications
Voltage DC
Accuracy* ¡¾ (0.7%+2)
Max. Resolution 1 mV
Maximum 600 V
Voltage AC
Accuracy* ¡¾ (1.0%+3)
Max. Resolution 1 mV
Maximum 600 V
Current DC
Accuracy* ¡¾ (1.0%+3) (111/112)
Max. Resolution 1 mA
Maximum 10 A
Current AC
Accuracy* ¡¾ (1.5%+3) (111/112)
Maximum 10 A
Max. Resolution 10 mA
Resistance
Accuracy* ¡¾ (0.9%+1)
Max. Resolution 0.1 ¥Ø
Maximum 40 M¥Ø
Capacitance
Accuracy* ¡¾ (1.9%+2)
Max. Resolution 1 nF
Maximum 10,000 µF
Frequency
Accuracy* ¡¾ (0.1%+2)
Max. Resolution 0.01 Hz
Maximum 50 kHz
Note
* Accuracies are best accuracies for each function

 

Environmental Specifications
Operating Temperature
  -10¡ÆC to +50¡ÆC
Storage Temperature
  -30¡ÆC to +60¡ÆC
Humidity (Without Condensation)
  0% - 95% (10¡ÆC - 30¡ÆC)
  0% - 45% (40¡ÆC - 50¡ÆC)
  0% - 75% (30¡ÆC - 40¡ÆC)

 

Safety Specifications
Overvoltage category
  EN 61010-1 to 600 V CAT III.
Agency Approvals
  UL, CSA, TÜV listed and VDE Pending

 

Mechanical & General Specifications
Size
  160 x 96 x 46 mm
Weight
  350 g
Warranty
  3 years
Battery Life
Alkaline: ~300 hours typical, without backlight