À̹ÌÁö detail
Digital Insulation Tester(KYORITSU/3007A),1000V/2000§Û
  • Á¦Á¶»çKYORITSU
  • ¸ðµ¨¸í3005A, 3007A
  • ÁÖ¿ä±â´É Àý¿¬ÀúÇ×½ÃÇè±â
»óÇ°»ó¼¼Á¤º¸

 









MODEL 3005A

• Bargraph to display insulation resistance.
• Displays the value of external AC voltage along with flashing symbol.
• Auto null function to automatically subtract the test lead resistance before displaying the real continuity resistance value.
• Live circuit warning beeper.
• Releasing the test button automatically discharges the charges stored in the circuit under test.
• 200mA continuity measuring current to IEC 61557.
• Minimum 1mA current on insulation tests to IEC 61557.     
  • ACV Resistance Continuitybuzzer AutoPowerOff
  • 250V 500V 1000V

Insulation Resistance

Test voltage250V/500V/1000V
Measuring ranges
(Mid-scale value)
20M¥Ø/200M¥Ø/2000M¥Ø
Output voltage on open circuitRated test voltage+20%, -0%
Nominal current1mA DC min.
Output short circuit current1.5 mA DC approx.
Accuracy¡¾1.5%rdg¡¾5dgt (20M¥Ø/200M¥Ø)
¡¾10%rdg¡¾3dgt (2000M¥Ø)

Continuity Test

Measuring ranges
(Mid-scale value)
20¥Ø/200¥Ø/2000¥Ø
Output voltage on open circuit7 - 12V DC
Measuring current200mA DC min.
Accuracy¡¾1.5%rdg¡¾5dgt (20¥Ø)
¡¾1.5%rdg¡¾3dgt (200¥Ø/2000¥Ø)

AC Voltage

AC voltage range0 - 600V AC
Accuracy¡¾5%rdg¡¾3dgt

General

Safety StandardIEC 61010-1 CAT III 300V Pollution Degree 2
IEC 61010-2-031 IEC 61557-1/2/4
IP RatingIEC 60529-IP54
EMC StandardIEC 61326-1
Power sourceR6 (AA) (1.5V) ¡¿ 8
Dimensions167(L) ¡¿ 185(W) ¡¿ 89(D)mm
Weight970g approx
Included Accessories7122B (Test leads) Pouch for test leads
8923 (F500mA/600V fuse) ¡¿ 2
R6 (AA) ¡¿ 8, Shoulder Strap
Instruction Manual

 



 

MODEL 3007A   Insulation Resistance
Test voltage250V/500V/1000V
Measuring ranges
(Mid-scale value)
20M¥Ø/200M¥Ø/2000M¥Ø
Output voltage on open circuitRated test voltage+20%, -0%
Nominal current1mA DC min.
Output short circuit current1.5 mA DC approx.
Accuracy¡¾1.5%rdg¡¾5dgt (20M¥Ø/200M¥Ø)
¡¾10%rdg¡¾3dgt (2000M¥Ø)

Continuity Test

Measuring ranges
(Mid-scale value)
20¥Ø/200¥Ø/2000¥Ø
Output voltage on open circuit7 - 12V DC
Measuring current200mA DC min.
Accuracy¡¾1.5%rdg¡¾5dgt (20¥Ø)
¡¾1.5%rdg¡¾3dgt (200¥Ø/2000¥Ø)

AC Voltage

AC voltage range0-600V AC
Accuracy¡¾5%rdg¡¾3dgt

General

Safety StandardIEC 61010-1 CAT III 300V Pollution Degree 2
IEC 61010-2-031 IEC 61557-1/2/4
IP RatingIEC 60529-IP54
EMC StandardIEC 61326-1
Power sourceR6 (AA) (1.5V) ¡¿ 8
Dimensions167(L) ¡¿ 185(W) ¡¿ 89(D)mm
Weight990g approx
Included Accessories7122B (Test leads) Pouch for test leads
8923 (F500mA/600V fuse) ¡¿ 2
R6 (AA) ¡¿ 8
Shoulder Strap