AC Clamp Meter(KYORITSU/2432,3), 400A
  • Á¦Á¶»çKYORITSU
  • ¸ðµ¨¸í2432, 2433, 2433R
  • ÁÖ¿ä±â´É ´ëÀü·ù ÃøÁ¤
»óÇ°»ó¼¼Á¤º¸




 

 

Leakage Clamp Meters

MODEL 2432

• High Sensitive Model
• Frequency Selector Switch to eliminate the effect of harmonics.
• Three AC current ranges:4mA/40mA/100A.
• Resolution 0.001mA.
  • ¥õ40 MAX100A Filter PeakHold10ms
AC A (50/60Hz)4/40mA/100A
¡¾1%rdg¡¾5dgt (4/40mA)
¡¾1%rdg¡¾5dgt (0 - 80A)
¡¾5%rdg (80.1 - 100A)
AC A (WIDE)4/40mA/100A
¡¾1%rdg¡¾5dgt [50/60Hz],
¡¾2.5%rdg¡¾10dgt [20Hz - 1kHz] (4/40mA)
¡¾1%rdg¡¾5dgt [50/60Hz],
¡¾2.5%rdg¡¾10dgt [40Hz - 1kHz] (0 - 80A)
¡¾5%rdg [50/60Hz],
¡¾10%rdg [40Hz - 1kHz] (80.1 - 100A)
Maximum circuit voltage600V AC/DC (between line/neutral)
300V AC/DC (against earth)
Conductor size ¨ª40mm max.
Frequency response20Hz - 1kHz (40Hz - 1kHz:100A)
Effect of External Stray Magnetic Field2mA AC approx. in proximity to a 15mm-dia
conductor carrying 100A AC
Safety StandardIEC 61010-1 CAT III 300V Pollution Degree 2
IEC 61010-2-032
Response Time Approx. 2 seconds
Power sourceTwo R03 or equivalent (DC1.5V) batteries
Dimensions185(L) ¡¿ 81(W) ¡¿ 32(D)mm
Weight290g approx.
Included Accessories 9097 (Carrying Case)
R03 (1.5V) ¡¿ 2
Instruction Manual
Optional Accessories 8008 (Multi-Tran)*

* This Multi-Tran can not be used for leakage current measurement 

 

 

Leakage Clamp Meters

MODEL 2433

• Frequency Selector Switch to eliminate the effect of harmonics.
• Three AC current ranges:40mA/400mA/400A.
• Resolution 0.01mA.
  • ¥õ40 MAX400A Filter PeakHold10ms
AC A (50/60Hz)40/400mA/400A
¡¾1%rdg¡¾5dgt (40/400mA)
¡¾1%rdg¡¾5dgt (0 - 350A)
¡¾2%rdg (350.1 - 399.9A)
AC A (WIDE)40/400mA/400A
¡¾1%rdg¡¾5dgt [50/60Hz],
¡¾2.5%rdg¡¾10dgt [20Hz - 1kHz] (40/400mA)
¡¾1%rdg¡¾5dgt [50/60Hz],
¡¾2.5%rdg¡¾10dgt [40Hz - 1kHz] (0 - 350A)
¡¾2%rdg [50/60Hz],
¡¾5%rdg [40Hz - 1kHz] (350.1 - 399.9A)
Maximum circuit voltage600V AC/DC (between line/neutral)
300V AC/DC (against earth)
Conductor size¨ª40mm max.
Frequency response20Hz - 1kHz (40Hz - 1kHz:400A)
Effect of External Stray Magnetic Field10mA AC approx. in proximity to a 15mm-dia
conductor carrying 100A AC
Safety StandardIEC 61010-1 CAT III 300V Pollution Degree 2
IEC 61010-2-032
Response TimeApprox. 2 seconds
Power sourceTwo R03 or equivalent (DC1.5V) batteries
Dimensions185(L) ¡¿ 81(W) ¡¿ 32(D)mm
Weight270g approx.
Included Accessories9097 (Carrying Case)
R03 (1.5V) ¡¿ 2
Instruction Manual
Optional Accessories8008 (Multi-Tran)*

* This Multi-Tran can not be used for leakage current measurement

 

 

Leakage Clamp Meters

MODEL 2433R

• Frequency Selector Switch to eliminate the effect of harmonics.
• Three AC current ranges:40mA/400mA/400A.
• Resolution 0.01mA.
  • TRUE RMS ¥õ40 MAX400A ACA

  • DATAHOLD PeakHold10ms Filter AutoPowerOff
AC A (50/60Hz)40/400mA/400A
¡¾1%rdg¡¾5dgt (40/400mA)
¡¾1%rdg¡¾5dgt (0 - 300A)
¡¾2%rdg (300.1 - 399.9A)
AC A (WIDE)40/400mA/400A
¡¾1%rdg¡¾5dgt [50/60Hz],
¡¾2.5%rdg¡¾10dgt [20Hz - 1kHz] (40/400mA)
¡¾1%rdg¡¾5dgt [50/60Hz],
¡¾2.5%rdg¡¾10dgt [40Hz - 1kHz] (0 - 300A)
¡¾2%rdg [50/60Hz],
¡¾5%rdg [40Hz - 1kHz] (300.1 - 399.9A)
Maximum circuit voltage600V AC/DC (between line/neutral)
300V AC/DC (against earth)
Conductor size¨ª40mm max.
Frequency response20Hz - 1kHz [40Hz - 1kHz:400A]
Effect of External Stray Magnetic Field10mA AC approx. in proximity to a 15mm-dia
conductor carrying 100A AC
Applicable standardsIEC 61010-1 CAT III 300V Pollution Degree 2
IEC 61010-2-032
Response TimeApprox. 2 seconds
Power sourceTwo R03 or equivalent (DC1.5V) batteries
Dimensions185(L) ¡¿ 81(W) ¡¿ 32(D)mm
Weight270g approx.
Included Accessories9052 (Carrying Case) R03 (1.5V) ¡¿ 2
Instruction Manual
Optional Accessories8008 (Multi-Tran)*