°í°´¼¾ÅÍ

Á¦Ç°Ä«Å×°í¸®

¿Â¶óÀι®ÀÇ ±â¼úÀÚ·á½Ç ¿À½Ã´Â±æ
  > Àü±âÀüÀÚ°èÃø±â > ¹èÀü¹Ý½ÃÇè¿ë > --->Ŭ·¥ÇÁÇüÀü·ù°è

--->Ŭ·¥ÇÁÇüÀü·ù°è

À̹ÌÁö detail
AC Clamp Meter(KYORITSU/2413F,R), 1000A
  • Á¦Á¶»çKYORITSU
  • ¸ðµ¨¸í2413F, 2413R
  • ÁÖ¿ä±â´É ´ëÀü·ù ÃøÁ¤
»óÇ°»ó¼¼Á¤º¸

 

 

Leakage Clamp Meters

KEW 2413F

• Extra wide transformer jaws are best suited for clamping on all three or four wires (3phases) together for leakage current measurement.
• Frequency filter switch to eliminate the effect of harmonics.
• Output terminal.
• Resolution 0.1mA.

 

 

  • ¥õ68 MAX1000A ACA DATAHOLD PeakHold10/100ms OutPut Filter

AC A (50/60Hz)

 

200mA/2/20/200A/1000A

¡¾1.5%rdg¡¾2dgt (200mA/2/20A)
¡¾2%rdg¡¾2dgt (200A 0 - 500A)
¡¾5.5%rdg (501 - 1000A)

AC A (WIDE)

200mA/2/20/200/1000A
¡¾1%rdg¡¾2dgt [50/60Hz],
¡¾3%rdg¡¾2dgt [40Hz - 1kHz] (200mA/2/20A)
¡¾1.5%rdg¡¾2dgt [50/60Hz],
¡¾3.5%rdg¡¾2dgt [40Hz - 1kHz] (200A/0 - 500A)
¡¾5%rdg [50/60Hz],
¡¾10%rdg [40Hz - 1kHz] (501 - 1000A)

Conductor size

¨ª68mm max.

Frequency response

40Hz - 1kHz

Effect of external stray magnetic field ¥õ15mm 100A

10mA AC max.

Output

Waveform :
AC200mV against the maximum value of each range (1000A range is 100mV)
Recorder :
DC200mV against the maximum value of each range (1000A range is 100mV)

Applicable standards

IEC 61010-1 CAT III 300V
IEC 61010-2-032

Power source

6F22 (9V) ¡¿ 1 *Continuous measuring time: Approx. 60 hours

Dimensions

250(L) ¡¿ 130(W) ¡¿ 50(D)mm

Weight

570g approx.

Included Accessories

9094 (Carrying Case)
6F22 ¡¿ 1
Instruction Manual

Optional Accessories

7073 (2WAY Output Cord)






Leakage Clamp Meters

KEW 2413R

• Large transformer jaws of 68mm diameter makes it possible to clamp on all three or four wires (3 phases) together for leakage current measurement.
• True RMS enables an accurate measurement for distorted waveforms.
• Measurement from mA up to AC 1000A
• Frequency filter switch to eliminate the effect of the harmonics.
• 2 way analogue output terminal
• Resolution 0.1mA

 

 

  • TRUE RMS ¥õ68 MAX1000A ACA DATAHOLD PeakHold10/100ms 

  • OutPut Filter Backlight
AC A (50/60Hz)

 

 

200mA/2/20/200/1000A
¡¾2.5%rdg¡¾5dgt (200mA/2/20A)
¡¾3.0%rdg¡¾5dgt (200A, 0 - 500A)
¡¾5.5%rdg (501 - 1000A) 

AC A (WIDE)200mA/2/20/200/1000A
¡¾1.8%rdg¡¾5dgt (50/60Hz) (200mA/2/20A)
¡¾2.0%rdg¡¾5dgt (50/60Hz) (200A, 0 - 500A)
¡¾5.0%rdg (50/60Hz) (501 - 1000A)
Crest factor3.0 or less
Conductor size¨ª68mm max.
Frequency response40Hz - 1kHz
OutputWaveform :
AC200mV against the maximum value of each range (1000A range is 100mV)
Recorder :
DC200mV against the maximum value of each range (1000A range is 100mV)
Applicable standardsIEC 61010-1 CAT III 300V Pollution degree 2
IEC 61010-2-032
Power source6F22 (9V) ¡¿ 1 *Continuous measuring time: Approx. 60 hours
Dimensions250(L) ¡¿ 130(W) ¡¿ 50(D)mm
Weight Approx. 570g (including battery)
Included Accessories9094 (Carrying Case)
6F22 ¡¿ 1
Instruction Manual
Optional Accessories7073 (2WAY Output Cord)