°í°´¼¾ÅÍ

Á¦Ç°Ä«Å×°í¸®

¿Â¶óÀι®ÀÇ ±â¼úÀÚ·á½Ç ¿À½Ã´Â±æ
  > Àü±âÀüÀÚ°èÃø±â > ¹èÀü¹Ý½ÃÇè¿ë > --->Àü·ÂºÐ¼®±â

--->Àü·ÂºÐ¼®±â

À̹ÌÁö detail
Power Quality Analyzer(HIOKI/PQ3100), 0.2%
  • Á¦Á¶»çHIOKI
  • ¸ðµ¨¸íPQ3100
  • ÁÖ¿ä±â´É Àü¿øÇ°ÁúºÐ¼®±â
»óÇ°»ó¼¼Á¤º¸

 


 

 

  

HIOKI / PQ3100  POWER QUALITY ANALYZER

3-Phase 4-Wire Power Quality Analyzer Compliant to IEC61000-4-30 Class S Standards and On-screen Guide to Deliver Easy Setup and Testing

 

 Hioki portable power meters and analyzers are best in class power measuring instruments for measuring single to three-phase lines with a high degree of precision and accuracy. The PQ3100 is a comprehensive but easy-to-use power quality analyzer for monitoring and recording power supply anomalies, allowing their causes to be quickly investigated, and also for assessing power supply problems such as voltage drops, flicker, harmonics, and other electrical issues. Key Features • Record data including voltage, current, power, harmonics, and flicker simultaneously along a single time axis (Flicker recording available in future firmware update) • Capture all power anomalies, including instantaneous outages, voltage drops, and frequency fluctuations, while simultaneously recording trend data • Quick Set: Easy-to-understand on-screen guide for measurement procedures • Bundled PQ ONE application software makes it easy to create reports • Record waveforms for up to 1 second before and 10 seconds after an anomaly occurs • Accurately measure DC currents over extended periods of time (with an AC/DC auto-zero current sensor) • Directly supply power to connected current sensors

 

 

Basic specifications (Accuracy guaranteed for 1 year, Post-adjustment accuracy guaranteed for 1 year)

Measurement line typeSingle-phase 2-wire, Single-phase 3-wire, Three-phase 3-wire or Three-phase 4-wire plus one extra input channel CH4 for voltage/current, (all channels AC/DC measurement)
Voltage rangesVoltage measurement: 1000.0 V rms or DC, Transient measurement 2.200 kV peak
Current ranges50.000 mA AC to 5.0000 kA AC, 10.000 A DC to 2.0000 kA DC
(depends on current sensor in use)
Power ranges50.000 W to 6.0000 MW (determined automatically based on current range in use)
Basic accuracyVoltage: ¡¾0.2% of nominal voltage, Current: ¡¾0.1 % rdg. ¡¾0.1 % f.s. + current sensor accuracy, Active power: DC ¡¾0.5 % rdg. ¡¾0.5 % f.s. + current sensor accuracy, AC ¡¾0.2 % rdg. ¡¾0.1 % f.s. + current sensor accuracy
Measurement items1. Transient over voltage : 200 kHz sampling
2. Frequency cycle : Calculated as one cycle
3. Voltage (1/2) RMS, Current (1/2) RMS: one cycle calculation refreshed every half cycle
4. Voltage swell, Voltage dips, Voltage interruption
5. Inrush current : half-cycle calculation
6. Frequency 200 ms: Calculated as 10 or 12 cycles
7. 10-sec frequency: Calculated as the whole-cycle time during the specified 10 s period
8. Voltage waveform peak, Current waveform peak
9. Voltage, Current, Active power, Apparent power, Reactive power, Active energy, Apparent energy, Reactive energy, Energy cost, Power factor, Displacement power factor, Voltage unbalance factor, Current unbalance factor
10. Voltage crest factor, Current crest factor
11. Harmonic/ Harmonic phase angle (voltage/ current), Harmonic power: 0 th to 50 th orders
12. Harmonic voltage-current phase angle: 1 th to 50 th orders
13. Total harmonic distortion factor (voltage/ current)
14. Inter harmonic (voltage/ current): 0.5 th to 49.5 th orders
15. K Factor (multiplication factor)
16. (Available in future firmware update) Instantaneous flicker value: As per IEC61000-4-15
17. (Available in future firmware update) IEC Flicker, ¥Ä V10 Flicker`
RecordMaximum recording interval: 1 year, Maximum number of recordable events: 9999 ¡¿ 365 days
InterfacesSD/SDHC card, RS-232C, LAN (HTTP server), USB 2.0
Display6.5-inch TFT color LCD (640 ¡¿ 480 dots)
Power supplyAC adapter Z1002 (100 V to 240 V AC, 50/60 Hz, rated current 1.7 A), Battery pack Z1003 (Continuous use: 8 hr, Charging time: Max. 5 hr 30 m with AC adapter)
Dimensions and mass300 mm (11.81 in)W ¡¿ 211 mm (8.31 in)H ¡¿ 68 mm (2.68 in)D, 2.5 kg (88.2 oz) (including battery pack)
AccessoriesInstruction manual ¡¿1, Measurement guide ¡¿1, Voltage cord L1000-05 ¡¿1 set (Red/Yellow/Blue/Gray/Black, Alligator clip ¡¿5, Spiral tube ¡¿5), Color spiral tube (for identifying clamp sensor color) ¡¿1 set, Spiral tube ¡¿5, AC adapter Z1002 ¡¿1, Strap ¡¿1, USB cable (1 m 3.28 ft length) ¡¿1, Battery pack Z1003 ¡¿1, PQ ONE (software, CD) ¡¿1

 

 

 

Options

Current input

For power or load current measurement (1 sensor necessary for single-phase measurements, and 2 or 3 sensors required for 3-phase measurements)

 

AC CURRENT SENSOR CT7126

60 A AC, ¥õ15 mm (0.59 in), 2.5 m (8.20 ft) cord length

AC CURRENT SENSOR CT7131

100 A AC, ¥õ15 mm (0.59 in), 2.5 m (8.20 ft) cord length

AC FLEXIBLE CURRENT SENSOR CT7040 series

• 10 Hz to 50 kHz (¡¾3dB) • 600A or 6000A AC rated • ¥õ 254 mm (10.00 in) loop dia. to ¥õ 100 mm (3.94 in), 3 loop diameters

Learn more

AC CURRENT SENSOR CT7136

600 A AC, ¥õ46 mm (1.81 in), 2.5 m (8.20 ft) cord length

Leak current input

*For leak current measurement (not capable of power measurement)

 

AC LEAKAGE CURRENT SENSOR CT7116

6 A AC, ¥õ40 mm (1.57 in), 2.5 m (8.20 ft) cord length

AC/DC current input

 

 

AC/DC AUTO-ZERO CURRENT SENSOR CT7731

・ DC to 5 kHz (-3dB) ・ Rated 100 A AC/DC ・ 1mV/A output ・¥õ 33 mm (1.30 in) core dia.

Learn more

AC/DC AUTO-ZERO CURRENT SENSOR CT7736

・ DC to 5 kHz (-3dB) ・ Rated 600 A AC/DC ・1mV/A output ・¥õ 33 mm (1.30 in) core dia.

Learn more

AC/DC AUTO-ZERO CURRENT SENSOR CT7742

・ DC to 5 kHz (-3dB) ・ Rated 2000 A AC/DC ・ 0.1mV/A output ・¥õ 55 mm (2.17 in) core dia.

Learn more

Storage media

SD Card Precaution

Use only the SD Card Z4001 sold by HIOKI. Compatibility and performance are not guaranteed for SD cards made by other manufacturers. You may be unable to read from or save data to such cards.

SD MEMORY CARD 2GB Z4001

For storing measurement data

SD MEMORY CARD Z4003

8 GB

Voltage input

*The L1000-05 is bundled

 

VOLTAGE CORD L1000-05

Red/ Yellow/ Blue/ Gray/Black each 1, 3 m (9.84 ft) length

GRABBER CLIP 9243

Attaches to the tip of the banana plug cable, Red/ Black: 1 each, 196 mm (7.72 in) length, CAT III 1000 V

MAGNETIC ADAPTER 9804-01

Attaches to the tip of cord, red ¡¿1, ¥õ11 mm (0.43 in)

MAGNETIC ADAPTER 9804-02

Attaches to the tip of cord, black ¡¿1, ¥õ11 mm (0.43 in)

Power supply

*The Z1002, Z1003 are bundled

 

AC ADAPTER Z1002

For main unit, 100 to 240 V AC

BATTERY PACK Z1003

NiMH, Charges while installed in the main unit

Cases

 

Waterproof Box
For outdoor installation; IP65 compliant, Contact Hioki for a quotation.

CARRYING CASE C1001

Soft type, Includes compartment for options

CARRYING CASE C1002

For the PW3198, hard trunk type, for storing options

CARRYING CASE C1009

Bag type, Includes compartment for options

Other options

 

 

CONVERSION CABLE L9910

Used to connect the current sensors with BNC terminal to PL14 terminal (example the PQ3100)

RS-232C CABLE 9637

For the PC, 9 pin - 9 pin, cross, 1.8 m (5.91 ft) length

LAN CABLE 9642

Straight Ethernet cable, supplied with straight to cross conversion adapter, 5 m (16.41 ft) length