°í°´¼¾ÅÍ

Á¦Ç°Ä«Å×°í¸®

¿Â¶óÀι®ÀÇ ±â¼úÀÚ·á½Ç ¿À½Ã´Â±æ
  > Àü±âÀüÀÚ°èÃø±â > ¹èÀü¹Ý½ÃÇè¿ë > --->³»¾Ð½ÃÇè±â

--->³»¾Ð½ÃÇè±â

À̹ÌÁö detail
Withstanding Voltage(KIKUSUI/TOS8030), 3kV/10mA
  • Á¦Á¶»çKIKUSUI
  • ¸ðµ¨¸íTOS8030
  • ÁÖ¿ä±â´É [3kV AC] Hipot Tester for simplified test
»óÇ°»ó¼¼Á¤º¸

 




 

 

 TOS8030

[3kV AC] Hipot Tester for simplified test

 

Outline

Model TOS8030 is a hipot tester developed by KIKUSUI, an international brand in the field of electrical safety testers, and is designed specifically for use in production and inspection lines in factories and plants. While retaining the high levels of quality and reliability inherent to our products, this tester is geared to provide what manufacturers want - compactness, light weight, and reasonable price.

 

Features

  • Hipot: 3 kVac/10 mA
  • Compact and lightweight (approx. 6 kg)
  • Digital timer (0.5 to 9.9 s; 1 to 99 s, Resolution: 0.1s)
  • Judgment range: 0.1 mA to 10 mA
  • Zero turn-on switch
  • Safety-conscious high-voltage output terminal and large DANGER lamp
  • Remote control function
  • Output of contact point signals such as PASS and FAIL

 

Lineup

ModelSpecification
TOS8030    Manual... 3kV, 10mA, AC voltage test only, Easy operation, Compact size, light weight
 

 

Options (Related products)

RC01-TOS
RC01-TOS
Option(s) for Electrical Safety Testers
Remote control box (For one hand operation, cable length:1.5m) Note1: The optional Adapter DD-5P/6P (DIN to Mini DIN) is required for the connection with TOS7200, Note2: The optional Adapter DD-5P/9P (DIN to Mini DIN) is required for the connection with TOS53XX

RC02-TOS
RC02-TOS
Option(s) for Electrical Safety Testers
Remote control box (For both-hand operation, cable length:1.5m) Note1: The optional Adapter DD-5P/6P (DIN to Mini DIN) is required for the connection with TOS7200, Note2: The optional Adapter DD-5P/9P (DIN to Mini DIN) is required for the connection with TOS53XX

TL01-TOS
TL01-TOS
Option(s) for Electrical Safety Testers
High-voltage test lead, 1.5m (5kV Max.)

TL02-TOS
TL02-TOS
Option(s) for Electrical Safety Testers
High-voltage test lead, 3m (5kV Max.)

HP01A-TOS
HP01A-TOS
Option(s) for Electrical Safety Testers
High-voltage test probe, Cable Length 1.8m (AC4kV,DC5kV Max.) , Note: The optional Adapter DD-5P/9P (DIN to Mini DIN) is required for the connection with TOS53XX

HP02A-TOS
HP02A-TOS
Option(s) for Electrical Safety Testers
High-voltage test probe, Cable Length 3.5m (AC4kV,DC5kV Max.), Note: The optional Adapter DD-5P/9P (DIN to Mini DIN) is required for the connection with TOS53XX

TL04-TOS
TL04-TOS
Option(s) for Electrical Safety Testers
High-voltage test lead, 1.5m(5kV Max.), for TOS1200, RL01-TOS

TL05-TOS
TL05-TOS
Option(s) for Electrical Safety Testers
High-voltage test lead, 1.5m(5kV Max.), for TOS7000 series,149-10A, RL01-TOS

RL01-TOS
RL01-TOS
Option(s) for Electrical Safety Testers
Load resistor for calibration of a W. Tester, The value of the resistor are selected to meet UL (UL 1492, UL1409, UL1410) requirements

TOS1200
TOS1200
Option(s) for Electrical Safety Testers
For the availability, please check with us.
Calibrator for the leakage current detecting sensitivity of a W. Tester

149-10A
149-10A
High Voltage Digital Voltmeter (AC/DC)
AC/DC +/-10kV, Used for high voltage: max. 10kV, For DC, AC (50 to 60Hz) voltage, High input impedance: 1000M ¥Ø