Primary Injection Test Set (OMICRON/CPC100), 400A/5kV
  • Á¦Á¶»çOMICRON
  • ¸ðµ¨¸íCPC 100
  • ÁÖ¿ä±â´É ºÎÇϽÃÇè, ±Ç¼öºñ½ÃÇè, °èÀü±â½ÃÇè
»óÇ°»ó¼¼Á¤º¸

 

 

 

 

 

 

 

 

 


 

 

 

 

​DESCRIPTION

Electrical tests on power transformers, current transformers, voltage transformers, rotating machines, grounding systems, lines and cables, and circuit breakers can be performed with the CPC 100.

The patented CPC 100 primary injection test system replaces several individual testing devices. This reduces the costs for training and transport, and cuts down testing time. Therefore, the CPC 100 is the ideal test set for substation asset commissioning and maintenance.

The CPC 100 is the base for multiple accessories. These facilitate further applications, such as power/dissipation factor measurements, as well as line and ground impedance measurements.


Key features

  • Up to 800 A or 2000 V with up to 5 kVA over a frequency range of 15 Hz - 400 Hz or 400 A DC
  • Excellent interference suppression facilitates measurement of small signals
  • Easy to transport (just 29 kg) - ideal for on-site testing
  • Testing templates, automatically generated testing procedures and test reports
  • Up to 2000 A or 12 kV through use of current or voltage amplifiers 

 



​ACCESSORIES


HGT1
The FFT Voltmeter HGT1 is used in connection with the CPC 100 and CP CU1
to measure step and contact voltages.
CP CB2
OMICRON¡¯s CP CB2 is an electronically controlled current booster for testing applications
requiring currents up to 2000 A.
CP CR500
The compensating reactor CP CR500 allows the insulation quality of generators,
motors, cables and other systems with large capacitances to be tested.
CP CU1
CP CU1 is a coupling unit designated for measurements with the CPC 100 test system
mainly on overhead lines and power cables.
CP DB1
The CP DB1 transformer discharge box facilitates fast discharging
of power transformers during the test process.
CP RC
The CP RC resonance circuit units together with the CPC 100 can be used for
voltage withstand testing of gas-insulated switchgears (GIS).
CP SB1
The transformer switch box CP SB1 was designed to measure ratio and winding
resistance and test the tap changer of power transformers.
The unit ensures faster, safer, more reliable, and more comfortable testing.
CP TC12
The CP TC12 oil test cell precisely determines the dielectric constant,
the dissipation factor (tan delta) and the power factor of insulating liquids
such as transformer oil.
CP TD1
The CP TD1 accessory is used in combination with TESTRANO 600,
CPC 100 or CPC 80 to perform power / dissipation factor and capacitance measurements.
PTM
The Primary Test ManagerTM (PTM) is the ideal software tool for
diagnostic testing of power transformers, current transformers, and circuit breakers.



​DOCUMENTS

 

 

Brochures

Papers & Articles

 

  CPC 100

Universal primary injection test set for substation assets