Partial Discharge Tester(OMICRON/MPD 600)
  • Á¦Á¶»çOMICRON
  • ¸ðµ¨¸íMPD 600
  • ÁÖ¿ä±â´É ºÎºÐ¹æÀü½ÃÇè±â
»óÇ°»ó¼¼Á¤º¸

 






 

 

 

OMICRON/MPD 600

High-end measuring and analysis system for partial discharges

 

The MPD 600 is a highly developed device for measuring partial discharges (PD). With excellent tools, even the smallest PD pulses are separated from interference and analyzed. The MPD 600 is suitable for many different PD testing applications.

With many complex test objects, e.g. generators, multiple simultaneous measurements offer a distinct advantage. An MPD can be effortlessly combined with other MPDs. It is the only system worldwide that records and analyzes the signals of all connected measurement points at the same time.

Hundreds of MPD systems are currently in use across the globe. Cable, transformer and machine manufacturers use the MPD 600 in their production facilities and for on-site partial discharge testing.


Key features

  • Unsurpassed immunity to interference for partial discharge measurements, even under difficult operating conditions
  • High measurement accuracy thanks to completely digital data processing
  • Quickly and easily extendible to a virtually unlimited number of channels
  • Recording and playback of measurements with full function control
  • IEC 60270-compliant partial discharge measurement, confirmed by an independent testing institute

Applications

  • Transformer testing
  • On-site testing and fault localization in cables
  • Gas-insulated switchgear (GIS), with extension also in the UHF range
  • Measurements on rotating machines
  • Lab measurements on medium and high voltage components

 

 

MBB1

The MBB1 is a measurement balanced bridge that enables you to perform reliable differential PD measurements in test environments with heavy interference.

 

 

  • RIV1

    Reliable PD measurements based on Radio Influence Voltage (RIV) according to NEMA and CISPR standards.

  • Bushing Adapters

    A selection of combinable adapters for secure connections to bushings, delivered in a handy case.


    • CAL 542

      Charge calibrators are used to inject a defined charge into and verify the measurement circuit.

    • CPL 542/543

      The CPL quadripole is an external measuring impedance for partial discharge measurements.

    • MCC 112/117/124

      The MCC 112, MCC 117 and MCC 124 are compact coupling capacitors for direct connection to the MPD measurement unit and for the usage in small routine test fields.


    • MCC 210

      The MCC 210 coupling capacitor is designed with a built-in quadripole measuring impedance and includes a dedicated space for the MPD measuring unit and the MPP power pack.

    • MCT 120

      High frequency current transformers pick up partial discharge (PD) signals in moderate heights and in safe distance from high voltage.
       

    • MCU 502

      The MCU is the transmitter between the MPD and the operating computer for PD measurements.


    • MPP 600

      The MPP battery powers a PD measuring device for more than 20 hours.

    • UHF 608

      The UHF 608 expands the measuring range of MPD 600 systems from 220 to 850 MHz.

    • UHF 620

      The UHF 620 extends the measurable bandwidth of the  600 up to the VHF and UHF range.


    • UHT1

      The UHT1 is a hatch-type UHF sensor used for detecting partial discharges (PD) in oil-paper-insulated power transformers. 

       

       

    • UVS 610

      The UVS 610 allows partial discharge (PD) measurements to be conducted in liquid-insulated power transformers.

    • UCS1

      The UCS1 sensor is designed for reliable partial discharge (PD) testing and monitoring of high-voltage (HV) cable terminations.