VLF High Voltage Test Set(b2/HVA45), 45kV, 0.1Hz, ¡¾1%
  • Á¦Á¶»çb2 electronic GmbH
  • ¸ðµ¨¸íHVA45, HVA45TD
  • ÁÖ¿ä±â´É 32kVrms VLF ½ÃÇè±â
»óÇ°»ó¼¼Á¤º¸

 






 

 

 

0.01 ~ 0.1Hz ÁÖÆļö°¡ °¡º¯µÇ´Â ½ÎÀÎÆÄ Ãâ·ÂÀÇ VLF ½ÃÇè±â ÀÔ´Ï´Ù.
Á¦Ç°¿¡ µû¶ó HVA45TD Á¦Ç°Àº Tandelta ÃøÁ¤ÀÌ ³»ÀåµÇ¾î ÀÖ½À´Ï´Ù.
22.9kV ÄÉÀ̺íÀÇ TD ±âÁØ(1.5U0) PD ±âÁØ(2U0) ¿¡ ¸Â´Â Á¦Ç°ÀÔ´Ï´Ù.
 

• VLF and DC Output
• Sheath Fault Location Mode
• Sheath Fault Location Mode​

• Vacuum Bottle Test
• Insulation Testing
• Insulation Testing​

 

The HVA45 is a truly compact and portable VLF test set system for testing medium voltage cables. It performs Bluetooth for further investigation and easy report creation on the PC Software.
Performance - the HVA45 offers outstanding features in terms of size, weight (36 kg) and performance (max. 10 ¥ìF). A dry design (no oil inside) makes the instruments nearly maintenance free.
Safety - The instrument has two independent earthing devices (electronic and mechanical discharging) and an integrated 12 kV feedback protection system to protect both operator and instrument.
Field use - A watertight and very rugged case with a protection class of IP67 makes additional transport boxes obsolete.
Connectivity - On site, no external PC is needed. All results can be downloaded later by USB or Bluetooth for further investigation and easy report creation on the PC Software.​

 

Features
• USB and Bluetooth connections
• Pure sinusoidal output voltage (load-independent)
• Output current 60 mA max.
• Highest test capacity of 10¥ìF
• Ultra light and compact weight (36 kg)
• Total protection – almost unbreakable, watertight, dustproof and corrosion proof case
• Protection class IP67 (with closed lid)
• Large Colour display (4,3¡±)
• USB and Bluetooth connections​

• Cable testing according:
• Easily exchangeable HV cable IEC60502-2:2014
• Programmable test sequences
• Upgradable with partial discharge diagnostic and Tan Delta system (optional)
• Integrated 12kV transient protection(50 Hz)
• Dual Discharge Device (DDD?), two integrated and automatic discharge devices
• Easily exchangeable HV cable​

• Intuitive menu operation
• Insulation Testing with Earth Fault Locator)1
• Vacuum Bottle Test
• Insulation Testing​
 