Motor Core Loss Tester(Phenix /CL Series)
  • Á¦Á¶»çPhenix
  • ¸ðµ¨¸íCL Series
  • ÁÖ¿ä±â´É Core Loss ½ÃÇèÀåºñ
»óÇ°»ó¼¼Á¤º¸







 

 

 

Motor Core L oss Test Sets

Test electric motors from fractional to 20,000 HP

-. Fully automated with data acquisition

-. True sine wave output ensures accurate and repeatable test results

-. Simple set-up and operation 

 

Test ing App licat ions
Perform core loss testing on stators, rotors, and armatures to insure the quality of a motor or motor rewind
• Perform hot spot testing to identify localized shorted laminations that cause hot spots and insulation failure in a motor
 

DESCRIPTION 

The Phenix Technologies Core Loss Test Set is a continuously variable sufficiently to locate hot spots.
armature cores. These units have very low distortion, independent of load and output setting. This insures test results that are both accurate and repeatable.
The basic test set includes complete instrumentation, output and voltmeter cables, omputer and printer. The computer is used for complete control, metering, data storage and valuation of test results.
Operation of the test set is as easy as hooking up the test leads, typing in the parameters of the test and pushing a button. The test set takes over from there; automatically ramps up the voltage, records the results, does all the necessary calculations and ramps the voltage back down.
The automated function eliminates operator error; several pre-programmed messages will alert the operator of test set up errors, saving time and increasing operator safety. A  tabase can be built for specific motors tested. Past results can be easily accessed when re-testing a motor that has been tested in the past, making trend analysis quick and easy.
The operating software interfaces with the test sets Programmable Logic Controller (PLC) that in turn guides the test set through its test functions.
The PLC eliminates a large portion of circuitry required in manual test units. With less ircuitry, the test set becomes much more reliable and easier to troubleshoot if a problem does occur.
Precision control of the output setting is possible with 3-5 ranges per output tap. This translates into 3-5 times greater regulation of the output voltage setting.
A meter calibration is done through the computer; saving time and insuring accurate eadings. There is no need to remove panels off the test set to calibrate the metering.
The duty cycle allows the operator to overexcite and heat the core sufficiently to locate hot spots.​

 