Measurement parameter | AC voltage (AC potential bridge) |
---|---|
Objects of measurement | Insulated conductors (IV or CV equivalent, min. 100 mm©÷ x-section), metal conductors Note: Not usable on shielded conductors |
Measurement range | 420.0V/ 600V AC (Auto) |
Measurement values | True RMS |
Max. rated voltage to earth | 600V AC rms |
Influence of adjacent wiring | ¡¾5% rdg. or less |
Temperature characteristics | 0.05 % rdg./ ¡ÆC |
Display | Digital LCD, max. 4200 digit (zero suppress at 10 digits or less) |
Display refresh rate | Approx. once every 0.6 seconds |
Display response | 2.4 s or less |
Functions | Data hold function, auto-power off, low battery warning |
Power supply | LR6 (AA) alkaline battery ¡¿6, Continuous use: 14 hr (Power ON, no measurement), or 1-minute measurements for 1000 times, or 5-minute measurements for 200 times |
Dimensions and mass | 51mm (2.01in) W ¡¿ 275mm (10.83in) H ¡¿ 37.5mm (1.48in) D (one probe), 670g (23.6oz) |
Accessories | Instruction manual ¡¿1, LR6 (AA) alkaline battery ¡¿6, Soft carrying case ¡¿1 |