Earth Clamp Tester(HIOKI/FT6380), 60A/1.5%
  • Á¦Á¶»çHIOKI
  • ¸ðµ¨¸íFT6380
  • ÁÖ¿ä±â´É Á¢ÁöÀúÇ×ÃøÁ¤±â
»óÇ°»ó¼¼Á¤º¸

 





 

 

 

Overview

The FT6380 measures grounding resistance simply by clamping to multiple-grounded ground wires. No auxiliary grounding rod is needed, and there is no need to disconnect the ground wire from the grounding rod. The compact, low-profile sensor can be used to clamp ground wires with ease, and also provide AC current measurement functionality and can measure currents ranging from leakage current on the order of several mA to load currents of up to 60 A. Key Features • Earth resistance measurement for multi-grounded systems • Measure leak current with absolute certainty with highly sensitive 0.01 mA resolution (at 20.00 mA range) • Measure load current up to 60.0 A range • Clamp at the narrowest point

 


FT6380 

 
 
CAT IV 600V

 

 

Product Video

 

 

 

¡á Basic specifications (Accuracy guaranteed for 1 year, Post-adjustment accuracy guaranteed for 1 year)

Measurement principleInstrument has two cores for voltage injection and current measurement. From the defined voltage and measured current, the total circuit loop resistance is calculated
Note: For multi grounded systems only. In a multi-grounded system, the larger the number of grounding poles, the more accurate the measured value.
Earthing resistance0.20 ¥Ø (0.01 ¥Ø resolution) to 1600 ¥Ø (20 ¥Ø resolution), 10 ranges, Zero suppression: Less than 0.02 ¥Ø,
Accuracy: ¡¾1.5 % rdg. ¡¾0.02 ¥Ø
AC Current measurement20.00 mA (0.01 mA resolution) to 60.0 A (0.1 A resolution), 5 ranges, Zero suppression: Less than 0.05 mA,
Accuracy: ¡¾2.0 % rdg. ¡¾0.05 mA (30 Hz to 400 Hz, True RMS), Crest factor 5.0 or less (for the 60 A range, 1.7 or less)
Max. allowable input100 A AC continuous, AC 200 A for 2 minutes or shorter (at 50/60 Hz, requires derating at frequency)
Max. rated voltage to earth600 V AC CAT IV
Memory function2000 data
Alarm functionFor resistance measurement and current measurement, Beeps when measured value is less than or greater than threshold
Other functionsData hold, Backlight, Filter, Auto power save
DisplayDigital LCD, max. 2000 dgt., Display refresh rate: 500 ms (2 times/s)
Waterproof and dustproofIP40 (EN60529) with clamp sensor closed
Communication interfaceN/A
Power supplyLR6 (AA) alkaline battery ¡¿2, Max. rated power: 450 mVA, Continuous use : 35 hr (in-house testing conditions)
Core jaw dia.¥õ 32 mm (1.26 in)
Dimensions and mass73 mm (2.87 in) W ¡¿ 218 mm (8.58 in) H ¡¿ 43 mm (1.69 in) D, 620 g (21.9 oz)
AccessoriesCarrying case ¡¿1, Resistance check loop (1 ¥Ø, 25 ¥Ø) ¡¿1, Strap ¡¿1, LR06 (AA) alkaline battery ¡¿2, Instruction manual ¡¿1