°í°´¼¾ÅÍ

Á¦Ç°Ä«Å×°í¸®

¿Â¶óÀι®ÀÇ ±â¼úÀÚ·á½Ç ¿À½Ã´Â±æ
  > Àü±âÀüÀÚ°èÃø±â > Àü±â°ø»ç¿ë > --->Á¢ÁöÀúÇ×ÃøÁ¤

--->Á¢ÁöÀúÇ×ÃøÁ¤

À̹ÌÁö detail
Earth Resistance & Resistivity Tester(KYORITSU/4106), 2.0%
  • Á¦Á¶»çKYORITSU
  • ¸ðµ¨¸íKEW 4106
  • ÁÖ¿ä±â´É Á¢ÁöÀúÇ×, ÀúÇ×·ü ÃøÁ¤
»óÇ°»ó¼¼Á¤º¸


 

KEW 4106

Earth Resistance & Resistivity Tester

• High test current up to 80mA yielding resolution of 0.001¥Ø on 2¥Ø range.
• Advanced Filtering method (based on FFT Fast Fourier Transform) reduces noise interference for obtaining stable measurements.
• Automatic and Manual selection of the Test Current Frequency in four bands (94/105/111/128Hz). In Automatic mode, KEW 4106 will select the most suitable Frequency.
• Several sub-results can be shown on the display: Resistance of the Auxiliary Earth Spikes, Frequency of Test Current, Voltage and Frequency of Interference (noise), Residual Resistance Rk, etc.
• Warning for excessive noise and high Auxiliary Earth Spikes resistance.
• Large Graphic Display with backlight for readings in poorly illuminated areas.
• Up to 800 measurement results can be saved in the memory and recalled on the display.
• The stored results can be transferred to a PC using the "KEW Report" software and a USB adaptor (Model 8212-USB) which are included.
• Robust design with IP54 protection.
  • Backlight
FunctionRangeResolutionMeasuring rangeAccuracy
Earth resistance
Re
(Rg at
¥ñ measurement)
2¥Ø0.001¥Ø0.03 - 2.099¥Ø¡¾2%rdg¡¾0.03¥Ø
20¥Ø0.01¥Ø0.03 - 20.99¥Ø¡¾2%rdg¡¾5dgt (*1)
200¥Ø0.1¥Ø0.3 - 209.9¥Ø
2000¥Ø1¥Ø3 - 2099¥Ø
20k¥Ø10¥Ø0.03k - 20.99k¥Ø
200k¥Ø100¥Ø0.3k - 209.9k¥Ø
Auxiliary earth resistance
Rh, Rs
   8% of Re+Rh+Rs
Earth resistivity
¥ñ
2¥Ø0.1¥Ø¡¤mm - 1¥Ø¡¤m
Autoranging
0.2 - 395.6¥Ø¡¤m¥ñ=2¡¿¥ð¡¿a¡¿Rg (*2)
20¥Ø0.2 - 3956¥Ø¡¤m
200¥Ø20 - 39.56k¥Ø¡¤m
2000¥Ø0.2 - 395.6k¥Ø¡¤m
20k¥Ø2.0 - 1999k¥Ø¡¤m
200k¥Ø
Series interference voltage
Ust (A.C only) (*3)
50V0.1V0 - 50.9Vrms¡¾2%rdg¡¾2dgt (50/60Hz)
¡¾3%rdg¡¾2dgt (40 - 500Hz)
Frequency
Fst
Autoranging0.1Hz
1Hz
40Hz - 500Hz¡¾1%rdg¡¾2dgt
Measuring methodEarth resistance: Fall-of-potential method
(currents and voltages measured via the Probes)
Measurement method of Earth Resistivity (¥ñ): Wenner 4-pole method
Series interference voltage (earth voltage)
RMS Rectifier (between the E-S Terminals)
Memory capacity800 data
Communication InterfaceModel 8212-USB Optical Adaptor
LCDDot-matrix 192¡¿64 monochrome
Over-range Indication"OL"
Overload Protectionbetween E-S(P) and between E-H(C) terminals AC280V / 10 sec.
Applicable standardsIEC 61010-1 CAT III 300V, CAT IV 150V Pollution degree 2
IEC 61010-031, IEC 61557-1, 5, IEC 61326-1 (EMC), IEC 60529 (IP54)
Power sourceDC12V : sizeAA manganese dry battery (R6) ¡¿ 8
(Auto power off: approx. 5 minutes)
Dimensions167(L) ¡¿ 185(W) ¡¿ 89(D) mm
Weightapprox. 900g (including batteries)
Accessories7229A (Earth precision measurement),
7238A (Simplified measurement test leads),
8032 (Auxiliary earth spikes [2 spiks/set])¡¿2 sets (4 spikes in total),
8200-04 (Cord reel [4 pcs])¡¿1 set,
8212-USB (USB adaptor with "KEW Report(Software)"),
9121 (Shoulder strap),
9125 (Carrying case),
R6 ¡¿ 8, Instruction manual, Calibration certificate
Optional8212-RS232C (RS232C adaptor with "KEW Report(Software)")

(*1) Auxiliary earth resistance is 100¥Ø with Rk correction
(*2) Depending on the measured Rg. Interval [a] between auxiliary earth spikes is 1.0 - 30.0m  
(*3) This instrument is NOT designed to measure line voltages on commercial powers.

Accessories/Optional Accessories /Related Products