À̹ÌÁö detail
Memory Recorder(HIOKI/8860,8861), DC 400V/10§Ö
  • Á¦Á¶»çHIOKI
  • ¸ðµ¨¸í8860-50, 8861-50
  • ÁÖ¿ä±â´É ÆÄÇüÃøÁ¤±â, µ¥ÀÌÅͷα×, ÆÄÇü±â·Ï
»óÇ°»ó¼¼Á¤º¸


 

 

 

MEMORY HiCORDER

8860-50, 8861-50

High-speed 16- or 32-channel Memory Recorders Offer Data Acquisition, Oscilloscope and Data Logger Functionality to Record Waveforms in Any Situation

 

Overview

Hioki Memory HiCorders are high-speed waveform monitoring and recording devices that can simultaneously measure multiple physical phenomena such as voltage, current, temperature, vibration, weight, acceleration and rotation due to complete isolation between channels and from each channel to the ground. More than just a digital oscilloscope, the 8860-50 and 8861-50 memory recorders accommodate plug-and-play input modules to meet applications such as monitoring commercial power supplies, fault analysis of electrical equipment, evaluating electric vehicle chargers, and analyzing conveyor belt speeds.

 

 

Key Features

•A faster CPU greatly enhances instrument operability and response.

•Multi-channel logging on up to 64 or 128 channels (with 8958 Scanner Unit)

•20 MS/s high-speed sampling and data acquisition (DAQ) (with 8956 Analog Unit)

•LAN/USB/PC-card slot built-in

•High-voltage input module for measuring high voltage directly

 

 

 

¡á Basic specifications (Accuracy guaranteed for 1 year, Post-adjustment accuracy guaranteed for 1 year)

 8860-508861-50
Number of input unitsMax. 4 unitsMax. 8 units
Number of channelsMax. 16 analog channels (Max. 64 channels when using the 8958) + standard 16 logic channelsMax. 32 analog channels (Max. 128 channels when using the 8958) + standard 16 logic channels
Measurement ranges (20 div full-scale)5 mV to 20 V/div, 12 ranges (when using the 8956), Resolution : 1/100 of range5 mV to 20 V/div, 12 ranges (when using the 8956), Resolution : 1/100 of range
Max. allowable inputDC 400V (when using the 8956)DC 400V (when using the 8956)
Frequency characteristicsDC to 10 MHz (-3dB, when using the 8956)DC to 10 MHz (-3dB, when using the 8956)
Time axis at memory function5 µs to 5 min/div, 26 ranges, sampling period : 1/100 of range, external sampling, dual timebase possible
Measurement functionsMEM (high-speed recording) REC (real-time recording) REC & MEM (realtime recording + high-speed recording) FFT (frequency analysis) Real-time Save (records directly to storage media)
Storage memory capacity12-bits ¡¿ 32M-words/ch (1ch at 8860-50, 2ch at 8861-50) to 2M-words/ch (16ch at 8860-50, 32ch at 8861-50)
*Memory capacity can be expanded 32 times. (Optional memory board)
Removable storageUSB 2.0 memory ¡¿ 3, PC card Type II slot ¡¿ 2, Hard disk drive (option) ¡¿ 1
Recording paper[Built in optional printer unit] A4: 216 mm (8.50 in) ¡¿ 30 m (98.43 ft), or A6: 112 mm (4.41 in) ¡¿ 18 m (59.06 ft) selectable, thermal paper roll, Recording speed : Max. 25 mm (0.98 in)/sec
Display10.4-inch SVGA-TFT color LCD (800 ¡¿ 600 dots)
External interfacesUSB 2.0, LAN, Monitor output (15 pin D-sub output), *GP-IB is Not Available
Power supply100 to 240 V AC (50/60 Hz) (220 VA max. printer not used)
12 V DC (use the DC power unit 9684 : option, factory installation only)
100 to 240 V AC (50/60 Hz) (280 VA max. printer not used)
12 V DC (use the DC power unit 9684 : option, factory installation only)
Dimensions and mass330 mm (12.99 in) W ¡¿ 250 mm (9.84 in) H ¡¿ 184.5 mm (7.26 in) D, 8 kg (282.2 oz) (printer not installed)330 mm (12.99 in) W ¡¿ 250 mm (9.84 in) H ¡¿ 284.5 mm (11.20 in) D, 10.5 kg (370.4 oz) (printer not installed)
AccessoriesQuick Start Manual ¡¿ 1, Input Module Guide ¡¿ 1, Instruction Manual ¡¿ 1, Analysis and Communication Supplement ¡¿ 1, Application Disk (WaveViewer Wv, communication commands table) ¡¿ 1, Power cord ¡¿ 1, Input cord label ¡¿ 1, Ferrite clamp (for LAN cable) ¡¿ 1