Measure Frequencies from 1 to 20 000 Hz.
Measure Low-Frequency Sound and
Noise with a Single Unit.
Measure Frequencies from 1 to 20 000 Hz. Measure Low-Frequency Sound and Noise with a Single Unit. | |
With the auto store function included as standard, as well as a timer function and external power supply support, the NL-62 is ideal for continuous measurement. Designed for intuitive ease of use, there is no more need to consult the manual during a measurement. The large 3-inch color screen is bright and easy to read. Sudden rainfall is also no problem, thanks to the water-resistant construction. Using the optional octave and 1/3 octave band real-time analysis program NX-62RT (under development), the unit can even operate as a frequency analyzer. The High-Precision Sound Level Meter NL-62 supports all your measurement needs. | |
Measurement Display (Level-Time graph) | Measurement Display (low-frequency sound) | Parameter Screen |
Menu screen | Help screen |
Water-resistant (Except for the microphone) | Use of rechargeable batteries |
Guaranteed water-resistant to at least level IP54 (resistant to spraying water).Helps reduce failures caused by sudden rain showers. * Mounting the All-weather windscreen or rainproof windscreen helps raise the water-resistant performance of the entire unit, so that the microphone will meet IPX3 specifications. | In these new models it is possible to use rechargeable batteries which make these meters environmentally-friendly. 16 hour continuous measurement is possible (when using eneloop? or dry alkaline batteries). |
・ Please use the dedicated charger to charged eneloop? batteries. ・ When using eneloop batteries, please read the eneloop? battery instruction manual. ・ eneloop? is a registered trademark of Panasonic group. |
Example of detailed recording | If the Lp is measured at 100 ms intervals and the Leq is simultaneously measured at 10 min intervals over a 24 h period, the total size of accumulated data is approximately 74 MB (reference value) |
1/3 octave band analysis screen (low range) | FFT analysis screen (x40) |
Total measuring time of Auto store function | Up to 1 000 h Equipped with a timer function |
Octave, 1/3 octave real-time analysis program NX-62RT | The NX-62RT is supplied on the 512 MB SD card. The 512 MB SD card can be used as a memory card after installing the program. |
1/3 octave band analysis screen (low range) | 1/3 octave band analysis screen (high range) | Overlay analysis screen |
1/3 octave band analysis screen (combined bands) | Measurement screen (Level-Time graph) |
Waveform recording program NX-42WR | The NX-42WR is supplied on the 2 GB SD card. The 2 GB SD card can be used as a memory card after installing the program. |
This function enables users to record sounds and processing sound to levels simultaneously. Recorded data can be played on computer and used for frequency analysis.(Uncompressed waveform WAVE file) Sampling at 48 kHz, 24 kHz, 12 kHz, Selection of 24 bit or 16 bit | Maximum recording time (16 bit)
|
Reverberation Time Measurement Program NX-42RV | The NX-42RV is supplied on the 512 MB SD card. The 512 MB SD card can be used as a memory card after installing the program. |
Measuring screen (graph) | Measuring screen (numeric) | Reverberation time decay curve screen | Result screen (T20/T30/Txx) |
FFT analysis program NX-42FT | The NX-42FT is supplied on the 512 MB SD card. The 512 MB SD card can be used as a memory card after installing the program. |
Analysis screen (x1) | Analysis screen (x40) | Overlay analysis screen |
Linear average screen | Top list screen |
All-weather | Rain-protection | Sound calibrator | Tripod | ||||
windscreen WS-15 This windscreen is designed for outdoor installations. It helps to reduce wind noise and is equipped with rainproof features that satisfy theIPX3 water-resistant specifications. It is used with a microphone extension cable. (Mounting adapter WS15006 required separately) | windscreen WS-16 This screen protects the microphone against rain for a short period of time.The rainproof performance of this windscreen is designed to satisfy the IPX3 water-resistant specifications. | NC-74 This Sound calibrator conforms to IEC 60942 (JIS C 1515), Class 1, providing a level of performance sufficient for calibrating the precision sound level meter. Specifications
| This stand can be used for general acoustic measurements. The sound level meter and microphone can be mounted on the stand. ST-80 ST-81 (For All-weather windscreen WS-15, use of ST-81 is recommended.) | ||||
This software allows you to load stored WAVE files from a RION sound level meter, vibration meter or data recorder. Octave, 1/3 octave, and FFT analyses can then be performed. Playback of the real sound files is also possible. | ||||||||||||||||||||||||||||||||
Frequency analysis screen | Frequency analysis screen | |||||||||||||||||||||||||||||||
|
Report preparation screen | Recommended computer specifications (Common for AS-60/60RT/60VM)
If AS-60/60RT/60VM is used on the NL-52/42, the NX-42EX is also needed. |
Supported models |
|
* Only auto store data are supported. |
Supported models |
|
* Only auto store data are supported. |
Supported models |
|
* Only auto store data are supported. |
Environment | Vehicles | Other industries |
---|---|---|
|
|
|
Applicable standards | NL-62 | |||
Applicable standards | IEC 61672-1: 2002 Class 1 ISO 7196: 1995 ANSI S1.4-1983 Type 1 ANSI S1.4A-1985 Type 1 ANSI S1.43-1997 Type 1 JIS C 1509-1: 2005 Class 1 | |||
---|---|---|---|---|
CE Marking (EMC Directive 2004/108/EC, Low Voltage Directive 2006/95/EC), WEEE Directives, Chinese RoHS (export model for China only) | ||||
Measurement functions | Simultaneous measurement of the following items, with selected time weighting and frequency weighting | |||
Processing (main ch) | Instantaneous sound pressure level: Lp Equivalent continuous sound pressure level: Leq Sound exposure level: LE Maximum sound pressure level: Lmax Minimum sound pressure level: Lmin Percentile sound levels: LN (0.1 to 99.9 %, 0.1-increment steps, max. 5 values) | |||
Processing (sub ch) | Instantaneous sound pressure level: Lp | |||
Additional processing | One of the following can be selected: C-weighted equivalent continuous sound level: LCeq G-weighted average sound level: LGeq C-weighted peak sound level: LCpeak Z-weighted peak sound level: LZpeak Power average of max. level in time weighted sound level interval LAtm5 I-time-weighted average sound level: LAIeq Max. value of I-time-weighted average sound level: LAImax * Because additional processing frequency characteristics are linked to sub channel frequency characteristics, LAtm5, LAIeq, LAImax can be selected when A characteristics are selected for sub channel. When C, G, or Z characteristics are selected, LCeq and LCpeak, LGeq, and LZ can be selected for additional processing. | |||
Microphone | Type | UC-59L | ||
Sensitivity level | -27 dB | |||
Measurement range | A-weighting: 25 dB to 138 dB C-weighting: 33 dB to 138 dB G-weighting: 43 dB to 138 dB Z-weighting: 50 dB to 138 dB C-weighting peak sound level: 60 dB to 141 dB Z-weighting peak sound level: 65 dB to 141 dB | |||
Inherent noise | A-weighting | 17 dB or less | ||
C-weighting | 25 dB or less | |||
G-weighting | 35 dB or less | |||
Z-weighting | 42 dB or less | |||
Frequency range | 1 Hz to 20 kHz | |||
Frequency weighting | A, C, G and Z | |||
Time weighting | F (Fast) and S (Slow), I (Impulse) and 10 s | |||
Level range | Single range (Linearity range: 113 dB) | |||
Bar graph display range max | Max. 110 dB (20 to 130 dB) | |||
Switching of bar graph display | Set the upper/ lower limit in 10 dB increments. | |||
RMS detection circuit | Digital processing method | |||
Sampling cycle | 20.8 ¥ìs (Lp, Leq, LE, Lmax, Lmin, Lpeak : sampling frequency: 48 kHz) 100 ms (LN ) | |||
Calibration | Electrical calibration performed according to IEC and JIS standards, using internally generated signals: acoustic calibration performed with the NC-74. | |||
Correction functions | Windscreen correction: Compliant with IEC 61672-1 and JIS C 1509-1 standards when the windscreen is installed. | |||
Diffuse sound field correction: Correction of frequency characteristics in order to comply with standards (ANSI S1.4) in diffuse sound field. | ||||
Delay time | The meter can be set to start measuring a specified time (OFF, 1, 3, 5 or 10 s) after the start button has been pressed or when a user-set trigger is exceeded. | |||
Back erase function | When the PAUSE key is pressed to pause measurement, the preceding (user selectable) 0, 1, 3 or 5 s data are excluded from processing. | |||
Display | Backlit semitransparent color TFT LCD display WQVGA (400 x 240 dots) * LCD with touch panel (Capacitive Touch Panel) | |||
Numerical display update frequency: 1 s Bar graph update frequency: 100 ms | ||||
Store | Manual | Data for measurement results are stored manually in single address increments. | ||
Number of data | Internal memory: max. 1 000 sets SD Card: depends on the capacity of the SD Card*1 | |||
Auto | Instantaneous values (Lp mode) and processed values (Leq mode) are stored continuously and automatically at preset intervals. | |||
Lp sampling cycle | 100 ms, 200 min, 1 s, Leq 1s and user selected time (up to 24 hours) | |||
Leq sampling cycle | 10 s, 1, 5, 10, 15, 30 min, 1, 8, 24 h, and user selected time (up to 24 hours) | |||
Measurement Time | Max. 1 000 h in Auto Lp storage mode, max. 100 000 addresses in Auto Leq storage mode (depends on the capacity of the SD card)*1 | |||
Data recall | Allows viewing of stored data | |||
Setup memory | Up to five setup configurations can be saved in internal memory, for later recall Start up via file settings previously stored on SD card possible | |||
Waveform recording*2 | ||||