À̹ÌÁö detail
Sound Level Meter (RION/NL62), 20 kHz/141dB
  • Á¦Á¶»çRION
  • ¸ðµ¨¸íNL62
  • ÁÖ¿ä±â´É ¼ÒÀ½°è
»óÇ°»ó¼¼Á¤º¸







 

 

 

 

 

Measure Frequencies from 1 to 20 000 Hz.
Measure Low-Frequency Sound and
Noise with a Single Unit.
Sound Level Meter Class1 NL-62
With the auto store function included as standard, as well as a timer function and external power supply support, the NL-62 is ideal for continuous measurement. Designed for intuitive ease of use, there is no more need to consult the manual during a measurement. The large 3-inch color screen is bright and easy to read. Sudden rainfall is also no problem, thanks to the water-resistant construction. Using the optional octave and 1/3 octave band real-time analysis program NX-62RT (under development), the unit can even operate as a frequency analyzer. The High-Precision Sound Level Meter NL-62 supports all your measurement needs.

Sound Level Meter Class1
(With low- frequency sound measurement function)
NL-62
Features
Large color LCD screen
Three-inch LCD screen with a touch panel High resolution screen is easy to see indoors or outdoors and even in the dark.
Three-inch LCD screen with a touch panelVariety of I/O Connections
No paper manual is needed.
User instructions and a help function can be easily accessed on the device.
NL-62 Measurement Display (Level-Time graph)NL-62 Measurement Display (Main and Sub Simultaneous Displays)NL-62 Parameter Screen
Measurement Display
(Level-Time graph)
Measurement Display
(low-frequency sound)
Parameter Screen
NL-62 Menu screenNL-62 Help screen
Menu screen
Help screen
Water-resistant (Except for the microphone)
Use of rechargeable batteries
Guaranteed water-resistant to at least level IP54 (resistant to spraying water).Helps reduce failures caused by sudden rain showers.

Waterproof NL-62
* Mounting the All-weather windscreen or rainproof windscreen helps raise the water-resistant performance of the entire unit, so that the microphone will meet IPX3 specifications.
In these new models it is possible to use rechargeable batteries which make these meters environmentally-friendly.
16 hour continuous measurement is possible
(when using eneloop? or dry alkaline batteries).rechargeable batteries NL-62
 
・ Please use the dedicated charger to charged eneloop? batteries.
・ When using eneloop batteries, please read the eneloop? battery
  instruction manual.
・ eneloop? is a registered trademark of Panasonic group.
Continuous detailed measurements for one month
This meter can be used to conduct long-term measurements, such as environmental measurements.(If an AC adapter is used)
Continuous detailed measurements
Example of detailed recording
If the Lp is measured at 100 ms intervals and the Leq is simultaneously measured at 10 min intervals
over a 24 h period, the total size of accumulated data is approximately 74 MB (reference value)
Functionality can be extended by a range of options
Add long-term data recording capability and frequency analysis function
1-3 octave band analysis screenAnalysis screen (x40)
1/3 octave band analysis screen
(low range)
FFT analysis screen (x40)
frequency analysis function(PC) NL-62
Data management screen of AS-60 software
Program function list
Program function list
Auto store function
This function enables continuous measurement in Lp mode (instantaneous SPL) and Leq mode (equivalent continuous SPL) to be conducted simultaneously.
Total measuring time of Auto store function
Up to 1 000 h  Equipped with a timer function
Lp mode (instantaneous SPL) and Leq mode (equivalent continuous SPL) concept
Lp mode and Leq mode NL-62
Comparator function
This function turns on when the open collector output exceeds the set value (max. applied voltage 24 V, max. current 60 mA, allowable dissipation 300 mW).
Comparator function NL-62
Continuous data output function
This function enables the continuous acquisition of instantaneous values and processed values during both USB and RS-232C communication.
This is a convenient function for users who can design their own control programs, where data has to be transferred continuously from the sound level meter to the computer.
Optional program function list
Optional program function list
Octave, 1/3 octave real-time analysis program
NX-62RT
SD-CARD NX-62RT
The NX-62RT is supplied on the 512 MB SD card.
The 512 MB SD card can be used as a memory card after installing the program.
By adding the NX-62RT program to the NL-62, octave band and 1/3 octave band real-time analysis can be realized. Saved analysis results can be loaded and shown in an overlay graph display together with current analysis data. NC curve graph display and NC value calculation/display are also possible.
NX-62RT 1-3 octave band analysis screen (low range)NX-62RT Overlay analysis screen (high range)NX-62RT Overlay analysis screen
1/3 octave band analysis screen
(low range)
1/3 octave band analysis screen
(high range)
Overlay analysis screen
NX-62RT 1/3 octave band analysis screen (combined bands)NX-62RT Measurement screen (T-L graph)
1/3 octave band analysis screen
(combined bands)
Measurement screen
(Level-Time graph)
Waveform recording program
NX-42WR
SD-CARD NX-42WR
The NX-42WR is supplied on the 2 GB SD card.
The 2 GB SD card can be used as a memory card after installing the program.
This function enables users to record sounds and
processing sound to levels simultaneously.
Recorded data can be played on computer
and used for frequency analysis.(Uncompressed waveform WAVE file)
Sampling at 48 kHz, 24 kHz, 12 kHz, Selection of 24 bit or 16 bit
Maximum recording time (16 bit)
Memory card
Sampling frequency
512 MB2 GB
48 kHz1 h4 h
24 kHz2 h8 h
12 kHz4 h16 h
 
Reverberation Time Measurement Program
NX-42RV
SD-CARD NX-42RV
The NX-42RV is supplied on the 512 MB SD card.
The 512 MB SD card can be used as a memory card after installing the program.
By adding the NX-42RV program to the NL-52/42, reverberation time measurements can be performed. The measurement method is the interrupted noise method. This program allows storage of reverberation time decay curves, T20/T30 calculation, Txx calculation (reverberation time calculation based on a user-defined interval) and averaged reverberation time results displayed on the SLM screen.
NX-42RV Measuring screen (graph)NX-42RV Measuring screen (numeric)NX-42RV Reverberation time decay curve screenNX-42RV Result screen (T20/T30/Txx)
Measuring screen (graph)
Measuring screen (numeric)
Reverberation time decay curve screen
Result screen (T20/T30/Txx)
FFT analysis program
NX-42FT
SD-CARD NX-42FT
The NX-42FT is supplied on the 512 MB SD card.
The 512 MB SD card can be used as a memory card after installing the program.
By adding the NX-42FT program to the NL-62, FFT analysis can be performed. The analysis frequency range is 20 kHz, with 8 000 spectrum lines (200 displayed). Saved analysis results can be loaded and shown in an overlay graph display together with current analysis data. Maximum zoom ratio is x40, and the top list screen can show up to 20 lines.
NX-42FT Analysis screen (x1)NX-42FT Analysis screen (x40)NX-42FT Overlay analysis screen
Analysis screen (x1)
Analysis screen (x40)
Overlay analysis screen
NX-42FT Overlay analysis screenNX-42FT Top list screen
Linear average screen
Top list screen
System construction
System construction
NL-62 System construction
Peripheral devices
Peripheral devices
All-weather
Rain-protection
Sound calibrator
Tripod
windscreen WS-15
WS-15
This windscreen is designed for outdoor installations. It helps to reduce wind noise and is equipped with rainproof features that satisfy theIPX3 water-resistant specifications. It is used with a microphone extension cable.
(Mounting adapter WS15006 required separately)
windscreen WS-16
WS-16
This screen protects the microphone against rain for a short period of time.The rainproof performance of this windscreen is designed to satisfy the IPX3 water-resistant specifications.
NC-74
WS-16
This Sound calibrator conforms to IEC 60942 (JIS C 1515), Class 1, providing a level of performance sufficient for calibrating the precision sound level meter.
 
Specifications
Nominal acoustic pressure
level
94 dB
Nominal frequency1 kHz
This stand can be used for general acoustic measurements. The sound level meter and microphone can be mounted on the stand.
ST-80
 
ST-81
(For All-weather windscreen WS-15, use of ST-81 is recommended.)
Waveform analysis software
AS-70
This software allows you to load stored WAVE files from a RION sound level meter, vibration meter or data recorder. Octave, 1/3 octave, and FFT analyses can then be performed. Playback of the real sound files is also possible.
Frequency analysis screen
Frequency analysis screen
Frequency analysis screen
Frequency analysis screen
Specifications
Waveform analysisCalculationsMaximum value, Minimum value, Average value, RMS, Variance, Differential and integral calculus, HPF, LPF
Frequency weightingZ, A, C, G, C to A, Lv (vertical) (JIS C 1510), Lv (horizontal) (JIS C 1510)
FFT analysisAnalysis points32 to 65 536 points
Display dataPower spectrum, Power spectral density, Spectrogram
Time weighting10 ms, F, 630 ms, S, 10 s
Octave band analysisApplicable standardsIEC 61260 Class 1 (JIS C 1514 Class 1)
Analysis frequency rangeOctave band 0.5 Hz to 16 kHz (16 bands)
1/3 octave band 0.4 Hz to 20 kHz (48 bands)
Recommended operating environment
CPUIntel Core¢â2 Duo 2 GHz or higher
RAM2 GB or more
(4 GB recommended)
HDD20 GB free or more
(100 GB or more recommended)
DISPLAYXGA (1 024 ¡¿ 768) or more
OSMicrosoft Windows XP Professional 32 bit,
7 Professional 32 bit / 64 bit,
8 Pro 32 bit/64 bit
Complete software for environmental measurements
Data management software for environmental measurement AS-60
Data management software for environmental measurement AS-60 enables the graph display of measurement data, arithmetic processing, excluded sound processing, preparation of reports, output of files, and playback of real sound files.
  • Easy to use
  • Reports easy to prepare

  • Simultaneous display of
    multiple data items
    (up to 8 data items)
  • Data on the data recorder
    can be loaded
    (CSV file for DA-40 Viewer)
  • Data combination



AS-60 Data management screen
Data management screen
AS-60 Report preparation screen
Report preparation screen
Recommended computer specifications
(Common for AS-60/60RT/60VM)
CPUIntel Core¢â2 Duo 2.0 GHz or higher
RAM2 GB or more
DISPLAYXGA (1024 x 768 pixels) or more,
at least 65 536 colors
OSMicrosoft Windows XP Professional 32 bit,
Microsoft Windows 7 Professional 32 bit and 64 bit
* If AS-60/60RT/60VM is used on the NL-52/42,
the NX-42EX is also needed.
Supported models
  • NL-62 *
  • NL-52/42 *
  • NL-32/31/22/21 *
  • DA-40 Viewer
* Only auto store data are supported.
Data management software for environmental measurement AS-60RT
(Includes the octave and 1/3 octave data management software)
Adds support for handling octave band analysis data to AS-60
AS-60RT is for managing NX-62RT/42RT or NA-28 data on a computer.


AS-60 Data management screen
Data management screen
Supported models
  • NX-62RT *
  • NX-42RT *
  • NA-28 *
* Only auto store data are supported.
Data management software for environmental measurement AS-60VM
(Includes the vibration level data management software)
Adds support for handling data measured with VM-53A to AS-60
Supported models
  • VM-53A*
* Only auto store data are supported.
Types of Measurement
Types of Measurement
EnvironmentVehiclesOther industries
  • Specified construction work noise
  • Specified factory noise
  • Road traffic noise (General road, highway)
  • Aircraft noise
  • Railway noise (inc. bullet trains)
  • Occupational health noise
  • Work environment noise
  • School health environmental noise
  • Low frequency noise from wind turbins
  • Low frequency noise from flyover bridges
  • Low frequency noise from transformers
  • Low frequency noise from boilers
  • Car interior noise (idling car)
  • Car exterior and interior noise (moving car)
  • Nearby exhaust sound
  • Tracking analysis of gear transmission
  • Computer acoustic power level measurement
  • Computer component (HDD / Fan) sound level
  • Home electronics sound rating ( home appliance sound evaluation)
  • Water heater noise
  • Construction machine, acoustic power level measurement
  • Vessel interior noise
  • Building acoustics (habitability /NC curve /sound pressure levels between rooms/evaluation of sound insulation /reverberation time measurement)
  • Measurement of silencer effect
  • Sound insulation measurement
  • Low frequency noise from vibration sifters
  • Low frequency noise from vacuum pumps
  • Low frequency noise from blowers
  • Low frequency noise from press machines


Specifications

Applicable standards 

NL-62
Applicable standardsIEC 61672-1: 2002 Class 1
ISO 7196: 1995
ANSI S1.4-1983 Type 1
ANSI S1.4A-1985 Type 1
ANSI S1.43-1997 Type 1
JIS C 1509-1: 2005 Class 1
CE Marking (EMC Directive 2004/108/EC, Low Voltage Directive 2006/95/EC),
WEEE Directives, Chinese RoHS (export model for China only)
Measurement functionsSimultaneous measurement of the following items, with selected time weighting and frequency weighting

Processing (main ch)Instantaneous sound pressure level: Lp
Equivalent continuous sound pressure level: Leq
Sound exposure level: LE
Maximum sound pressure level: Lmax
Minimum sound pressure level: Lmin
Percentile sound levels: LN (0.1 to 99.9 %, 0.1-increment steps, max. 5 values)
Processing (sub ch)Instantaneous sound pressure level: Lp
Additional processingOne of the following can be selected:
C-weighted equivalent continuous sound level: LCeq
G-weighted average sound level: LGeq
C-weighted peak sound level: LCpeak
Z-weighted peak sound level: LZpeak
Power average of max. level in time weighted sound level interval LAtm5
I-time-weighted average sound level: LAIeq
Max. value of I-time-weighted average sound level: LAImax
* Because additional processing frequency characteristics are linked to sub channel frequency characteristics, LAtm5, LAIeq, LAImax can be selected when A characteristics are selected for sub channel. When C, G, or Z characteristics are selected, LCeq and LCpeak, LGeq, and LZ can be selected for additional processing.
MicrophoneTypeUC-59L
Sensitivity level-27 dB
Measurement rangeA-weighting: 25 dB to 138 dB
C-weighting: 33 dB to 138 dB
G-weighting: 43 dB to 138 dB
Z-weighting: 50 dB to 138 dB
C-weighting peak sound level: 60 dB to 141 dB
Z-weighting peak sound level: 65 dB to 141 dB
Inherent noiseA-weighting17 dB or less
C-weighting25 dB or less
G-weighting35 dB or less
Z-weighting42 dB or less
Frequency range1 Hz to 20 kHz
Frequency weightingA, C, G and Z
Time weightingF (Fast) and S (Slow), I (Impulse) and 10 s
Level rangeSingle range (Linearity range: 113 dB)

Bar graph display range maxMax. 110 dB (20 to 130 dB)
Switching of bar graph displaySet the upper/ lower limit in 10 dB increments.
RMS detection circuitDigital processing method
Sampling cycle20.8 ¥ìs (Lp, Leq, LE, Lmax, Lmin, Lpeak : sampling frequency: 48 kHz)
100 ms (LN )
CalibrationElectrical calibration performed according to IEC and JIS standards, using internally generated signals: acoustic calibration performed with the NC-74.
Correction functionsWindscreen correction:
Compliant with IEC 61672-1 and JIS C 1509-1 standards when the windscreen is installed.
Diffuse sound field correction:
Correction of frequency characteristics in order to comply with standards (ANSI S1.4) in diffuse sound field.
Delay timeThe meter can be set to start measuring a specified time (OFF, 1, 3, 5 or 10 s) after the start button has been pressed or when a user-set trigger is exceeded.
Back erase functionWhen the PAUSE key is pressed to pause measurement, the preceding (user selectable) 0, 1, 3 or 5 s data are excluded from processing.
DisplayBacklit semitransparent color TFT LCD display WQVGA (400 x 240 dots)
* LCD with touch panel (Capacitive Touch Panel)
Numerical display update frequency: 1 s
Bar graph update frequency: 100 ms
StoreManualData for measurement results are stored manually in single address increments.

Number of dataInternal memory: max. 1 000 sets
SD Card: depends on the capacity of the SD Card*1
AutoInstantaneous values (Lp mode) and processed values (Leq mode) are stored continuously and automatically at preset intervals.

Lp sampling cycle100 ms, 200 min, 1 s, Leq 1s and user selected time (up to 24 hours)
Leq sampling cycle10 s, 1, 5, 10, 15, 30 min, 1, 8, 24 h, and user selected time (up to 24 hours)
Measurement TimeMax. 1 000 h in Auto Lp storage mode, max. 100 000 addresses in Auto Leq storage mode (depends on the capacity of the SD card)*1
Data recallAllows viewing of stored data
Setup memoryUp to five setup configurations can be saved in internal memory, for later recall Start up via file settings previously stored on SD card possible
Waveform recording*2